Data Centers

What is Free Cooling?

Definition

Free cooling uses outside air or water that is cooler than the return temperature to reduce or eliminate the need for mechanical refrigeration in data center cooling systems.

Free cooling is a method of rejecting heat from a data center by using ambient environmental conditions instead of running compressors or chillers. It works by drawing in outside air when the temperature and humidity are within acceptable ranges, or by using a water-side economizer that circulates cool water from a cooling tower or dry cooler directly to the computer room air handlers. The key principle is that the heat rejection medium (air or water) is naturally cooler than the data center return air temperature, so mechanical cooling can be bypassed or partially supplemented.

In practice, free cooling is implemented through air-side economizers, which use dampers and fans to bring outside air directly into the server halls, or water-side economizers, which use a heat exchanger to transfer heat from the building cooling loop to an external water loop without running the chiller compressor. Modern data centers often combine free cooling with evaporative pre-cooling or adiabatic systems to extend the operating range in warmer climates. The effectiveness of free cooling depends on the local climate; it is most efficient in temperate or cold regions where ambient temperatures fall below the data center supply setpoint for many hours per year.

Free cooling is a mature energy-saving strategy in the data center industry. It directly reduces the power usage effectiveness (PUE) by lowering the energy consumed by cooling infrastructure, which can account for 30-40% of total data center energy. Standards such as ASHRAE TC 9.9 provide environmental envelopes that define allowable temperature and humidity ranges for IT equipment, enabling operators to safely use free cooling for longer periods. While free cooling can reduce mechanical cooling load by 60-90% in suitable climates, it requires careful filtration, humidity control, and monitoring to protect sensitive electronics from particulates and condensation.

Key facts

  • Free cooling can reduce data center cooling energy use by 60-90% in suitable climates.
  • Air-side economizers bring outside air directly into the server room; water-side economizers use external water loops.
  • ASHRAE TC 9.9 guidelines define allowable temperature and humidity ranges for safe free cooling operation.
  • Free cooling is most effective in temperate or cold climates but can be extended with evaporative pre-cooling.
  • Proper filtration and humidity control are required to prevent contamination and condensation in air-side systems.

How it works in practice

A data center in Oregon with an average annual outdoor temperature of 11 degrees Celsius uses an air-side economizer. When the outside air is below 18 degrees Celsius and humidity is between 20-80%, the system opens dampers and shuts off the chiller. Over a year, the chiller runs only 1,200 hours instead of 8,760, saving approximately 70% of cooling energy and improving PUE from 1.6 to 1.2.

Related terms

Air-side economizer Water-side economizer Power usage effectiveness (PUE) ASHRAE TC 9.9 Evaporative cooling Chiller

References

More in Data Centers

Carrier Hotel

A Carrier Hotel is a physical facility where multiple telecommunications carriers co-locate equipment and tenants can cross-connect directly to any carrier's network without using a third-party provider.

Carrier Neutral

A data center facility owned by an operator that does not sell network transit, allowing tenants to connect to multiple competing carriers and internet service providers.

Concurrent Maintainability

Concurrent maintainability is the ability to perform planned maintenance on any single component inside a datacenter without disrupting the IT load.

Data Center Tier Classification

The Uptime Institute's Data Center Tier Classification is a standard methodology for rating data center infrastructure based on redundancy, capacity, and availability, ranging from Tier I (basic) to Tier IV (fault-tolerant).

Edge Data Center

An edge data center is a small, distributed facility located close to end users to minimize latency and support real-time applications, often deployed as prefabricated units and operated remotely.

Hot Aisle / Cold Aisle

Hot Aisle / Cold Aisle is a data center rack layout design that alternates rows of server intakes and exhausts to separate cool supply air from hot exhaust air, improving cooling efficiency.

Hyperscale Data Center

A hyperscale data center is a massive, single-tenant facility built by cloud, internet, or social-media giants to support tens of megawatts of IT load and hundreds of thousands of servers.

Internet Exchange Point

A physical infrastructure facility where multiple autonomous networks interconnect to exchange traffic directly, bypassing transit ISPs to reduce latency and cost.

kVA

kVA (kilovolt-ampere) is a unit of apparent power used to rate electrical equipment like UPSes and PDUs, equal to 1,000 volt-amperes, and differs from kilowatts when the power factor is not 1.0.

Liquid Cooling

Liquid cooling uses a working fluid to remove heat from electronic components, offering higher efficiency than air cooling for high-density AI accelerators.

Who Is Online

In total there are 53 users online: 0 registered, 47 guests and 6 bots.

Most users ever online was 5,555 on 17 Jul 2026, 3:23 am.

Bots: Applebot Baiduspider Other Bot Other Crawler PetalBot SemrushBot

Users active in the past 15 minutes. Total registered members: 369